R32 R290 EVI DC Inverter Multifunction Air-to-water Heat Pump BLB1I-100S 130S BLB3I-130S 180S
-
• R290 / R32 Low GWP Green Refrigerant
To reduce carbon emission to the environment and curb global warming, O.S.B.develops R290 air to water heat pump. With many advantages such as low carbon emission and high efficiency, R290 refrigerant is recognized as a refrigerant with the most development potential in the industry, which contributes to the reduction of carbon emission and help achieve the global goal of carbon neutrality.
-
•High Efficiency A+++ Energy Level
O.S.B. Air to Water Heat Pump is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only use R290 green gas and inverter technology, but also is rated with A+++ energy label. With top energy rating A+++, the unit is energy efficient and can greatly reduce energy bills for users
-
• Full DC Inverter Technology
Perfectly combines eco-friendly R290 refrigerant and inverter technology to produce efficient house heating/cooling and hot water even under extreme cold climate.
-
•Stable Running at -25℃ Ambient Temperature
Thanks to the unique Inverter EVI technology, can operate efficiently at -25°C, maintain high COP and reliable stability. Intelligent control, any weather available, automatic load adjust under different climate and environment to satisfy the demands of summer cooling, winter heating and hot water throughout the year.
-
•High Outlet Water Temperature
Maximum outlet temperature can be up to 60 deg C.
-
•Noise Reduction Technology
O.S.B. dedicates to creating super quiet running environment for the user. DC inverter heat pump adopts multiple noise reduction technologies, every product has been repeatedly tested and optimized.
-
• Smart Mobile WIFI APP
The intelligent controller is used to realize the linkage control between the heat pump unit and the terminal application to improve the operation efficiency. Through the WIFI APP, users can operate their devices from their smartphones anytime and anywhere.
-
• Wide Application
Meet multi-purpose needs throughout the year: space heating, cooling, domestic hot water.
-
• Unique Functions and Protections
There are multiple intelligent functions: memory function/ timer/ temperature control/ malfunction detect and 4-way protections: water lack protection/ system pressure protection/ abnornmal alert/ brust protection on heat exchanger
-
• Quality-guranteed Components
Use international famous brand components equipping
Model | BB11-100s | BB11-130S | BB11-180S | BB31-180S | Measuring conditions | ||
Refrigerant | R32 | R32 | R32 | R32 | |||
Suitable room size | m² | 170 | 240 | 320 | 320 | ||
Water production | L/h | 180 | 250 | 340 | 340 | ||
Power supply | VPh/Hz | 220~240/1/50-60 | 220~240/1/50-60 | 220~240/1/50-60 | 380/3/50-60 | ||
Air heating | Rated heating capacity | kw/Btu | 8.5/28990 | 12/40932 | 16/54576 | 16/54576 | Dry bulb:7℃ Wet bulb:6℃ Water inlet:30℃ Water outlet:35℃ |
Heating input power | kw | 1.89 | 2.45 | 3.56 | 3.56 | ||
Running current | A | 8.6 | 11.3 | 16.2 | 5.5*3 | ||
cOP | w/w | 4.5 | 4.9 | 4.5 | 4.5 | ||
Air heating | Rated heating capacity | kw/Btu | 8.5/28990 | 12/40932 | 16/54576 | 16/54576 | Dry bulb:7℃ Wet bulb:6℃ Water inlet:40℃ Water outlet:45℃ |
Heating input power | kw | 2.43 | 3.3 | 4.6 | 4.6 | ||
Running current | A | 11 | 15.2 | 20.1 | 7.1*3 | ||
cOP | w/w | 3.5 | 3.7 | 3.5 | 3.5 | ||
Domestichot water | Rated heating capacity | kw/Btu | 8.5/28990 | 12/40932 | 16/54576 | 16/54576 | Dry bulb:7℃ Wet bulb:6℃ Water inlet:47℃ Water outlet:55℃ |
Heating input power | kw | 3 | 4 | 5.7 | 5.7 | ||
Running current | A | 13.7 | 18.2 | 26 | 8.7*3 | ||
cOP | w/w | 2.8 | 3 | 2.8 | 2.8 | ||
Air cooling | Rated cooling capacity | kw/Btu | 8/27280 | 12/40932 | 14.8/50482.8 | 14.8/50482.8 | Dry bulb:35℃ Wet bulb:24℃ Water inlet:23℃ Water outlet:18℃ |
Cooling input power | kw | 2.43 | 3.33 | 4.35 | 4.35 | ||
Running current | A | 11.1 | 15.2 | 20 | 6.7*3 | ||
HONOR | w/w | 3.3 | 3.6 | 3.4 | 3.4 | ||
Air cooling | Rated cooling capacity | kw/ Btu | 7.4/25240 | 11.5/39226.5 | 14/47754 | 14/47754 | Dry bulb:35℃ Wet bulb:24℃ Water inlet:12℃ Water outlet:7℃ |
Cooling input power | kw | 3.1 | 4.26 | 5.6 | 5.6 | ||
Running current | A | 14.1 | 19.6 | 25.8 | 8.6*3 | ||
HONOR | w/w | 2.4 | 2.7 | 2.5 | 2.5 | ||
Max outlet water temp | ℃ | 55 | 55 | 55 | 55 | ||
Applicable ambient temp | ℃ | -15~43 | -15~43 | -15~43 | -15~43 | ||
Noise | dB(A) | 60 | 65 | 65 | 65 | ||
Water connections | Inch | 1" | 1" | 1" | 1" | ||
Compressor type | Rotary | Rotary | Rotary | Rotary | |||
Fan qty | PC | 1 | 2 | 2 | 2 | ||
Net dimensions | mm | 1115x470x935 | 1415x470x1250 | 1415x470x1250 | 1415x470x1250 | ||
Packing dimensions | mm | 1200x480x1090 | 1520x480x1380 | 1520x480x1380 | 1520x480x1380 | ||
Erp energy efficiency | 35℃A+++/55℃A++ |
Model | BLB1I-100S | BLB1I-130S | BLB3I-130S | BLB3I-180S | ||
Refrigerant | R32 | R32 | R32 | R32 | ||
Suitable room size | ㎡ | 54-220 | 90-320 | 90-320 | 140-420 | |
Water production | L/h | 195 | 280 | 280 | 370 | |
Power supply | V/Ph/Hz | 220-240/1/50-60 | 220-240/1/50-60 | 380/3/50-60 | 380-3/50-60 | |
Air heating/ DHW | Rated heating capacity | kw | 2.7-11 | 4.5-16 | 4.5-16 | 7-21 |
BTU | 9200-37520 | 15300-54500 | 15300-54500 | 23800-71630 | ||
Heating input power | kw | 1.04-3.44 | 1.67-4.85 | 2.6*3-7.5*3 | 3.9*3-9.5*3 | |
Running current | A | 4.8-15.8 | 7.7-22.3 | 7.7-22.3 | 11.5-28.4 | |
COP | w/w | 2.6-3.2 | 2.7-3.3 | 2.7-3.3 | 2.8-3.4 | |
Air cooling | Rated cooling capacity | kw | 2.5-7.5 | 3.8-11 | 3.8-11 | 4.8-14.5 |
BTU | 8520-25580 | 12960-37520 | 12960-37520 | 16370-49450 | ||
Cooling input power | kw | 1.14-4.42 | 1.81-6.88 | 1.81-6.88 | 2.18-8.53 | |
Running current | A | 5.3-20.1 | 8.3-31.6 | 2.9*3-10.6*3 | 3.5*3-13.1*3 | |
HONOR | w/w | 1.7-2.2 | 1.6-2.1 | 1.6-2.1 | 1.7-2.2 | |
Max outlet water temp | ℃ | 55 | 55 | 55 | 55 | |
Applicable ambient temp | ℃ | -25~43 | -25~43 | -25~43 | -25~43 | |
Noise | dB(A) | 55 | 60 | 60 | 60 | |
Water connections | Inch | 1" | 1" | 1" | 1" | |
Compressor type | Rotary | Rotary | Rotary | Rotary | ||
Net dimensions | mm | 1115*470*935 | 1415*470*1250 | 1415*470*1250 | 1415*470*1250 | |
Packaging dimensions | mm | 1215*470*935 | 1520*490*1400 | 1520*490*1400 | 1520*490*1400 | |
Electric heater | kw | 3 | 3 | 3 | 3 | |
Fan qty | PC | 1 | 2 | 2 | 2 | |
Erp energy rating | 35℃ A+++/55℃ A++ | |||||
Measuring conditions: | Air heating: Dry bulb:7℃, Wet bulb:6℃. Water outlet:45℃. Air cooling: Dry bulb:35℃,Wet bulb:24℃. Water inlet:12℃. |
Model | BLB1I-070S | BLB1I-100S | BLB1I-130S | BLB3I-180S | ||
Refrigerant | R290 | R290 | R290 | R290 | ||
Suitable room size | ㎡ | 62-170 | 84-240 | 108-300 | 160-440 | |
Power supply | V/Ph/Hz | 220~240/1/50-60 | 220~240/1/50-60 | 220~240/1/50-60 | 380/3/50-60 | |
Air heating/ DHW | Rated heating capacity | kw | 3.1-8.5 | 4.2-12 | 5.4-15 | 8-22 |
BTU | 10570-29000 | 14320-40930 | 18420-51160 | 27280-75000 | ||
Heating input power | kw | 0.66-2.02 | 0.9-2.86 | 1.2-3.85 | 2-6.5 | |
Running current | A | 2.9-9.2 | 4.2-13.2 | 5.5-17.7 | 3.2*3-10.4*3 | |
COP | w/w | 4.2-4.7 | 4.2-4.7 | 3.9-4.5 | 3.4-4 | |
Air cooling | Rated cooling capacity | kw | 1.2-5.7 | 3-8.4 | 3.6-10.5 | 4.2-15 |
BTU | 4090-19400 | 10230-28650 | 12280-35800 | 14300-51160 | ||
Cooling input power | kw | 0.65-2.4 | 1.25-4 | 1.12-4.5 | 1.8-7.3 | |
Running current | A | 2.9-10.5 | 5.8-18.5 | 4.9-19.6 | 2.9*3-11.7*3 | |
HONOR | w/w | 1.8-2.3 | 2.1-2.4 | 2.3-3.2 | 2.05-2.3 | |
Max outlet water temp | ℃ | 60-75 | 60-75 | 60-75 | 60-75 | |
Applicable ambient temp | ℃ | -25-43 | -25-43 | -25-43 | -25-43 | |
Noise | d B(A) | 50 | 55 | 60 | 60 | |
Water connectionns (air heating/cooling) | Inch | 1" | 1" | 1" | 1" | |
Compressor qty | PC | 1 | 1 | 1 | 1 | |
Compressor type | Rotary | Rotary | Rotary | Rotary | ||
Fan qty | PC | 1 | 1 | 2 | 2 | |
Net dimension LxWxH | MM | 1115*470*685 | 1115*470*935 | 1115*470*1250 | 1415*470*1250 | |
Packing dimension LxWxH | MM | 1220*480*710 | 1200*480*1090 | 1200*480*1380 | 1520*480*1380 | |
Auxiliary electrical heating | KW | 3 | 3 | 3 | 3 | |
ErP Energy efficiency grade | 35℃A+++/55℃A++ | |||||
Measuring conditions: | Air heating: Dry bulb:7℃, Wet bulb:6℃. Water outlet:45℃. Air cooling: Dry bulb:35℃,Wet bulb:24℃. Water inlet:12℃. |